震旦218打印机出现C-2152是什么原因
更新时间:2026/11/23 3:54:29,view:834苏州震旦218打印机售后服务中心客服热线69616769,苏州震旦打印机售后维修电话,震旦打印机售后网点,震旦218显示c2152怎么返回,adc错误c2152,ADC提示C2152,ADC显示C-2152,打印机报C-2152什么原因,代码c2152,AD出现2152,ad更换载体后初始,ADC纸张设置步骤,出p-21,adc出故障P-6,adc故障代码c-2512,AD-复印完提示装纸尺寸不正确,ADC纸盒A4检测出错–纸盒尺寸错误...,ad打印机修理视屏,218维修视频2026/11/2

Code C2152
转印带缩回操作期间,转印带缩回传感器无法在转印
带缩回离合器开启后的预定时间间隔内检测到转印带
是否位于其缩回位置。
转印带加压操作期间,转印带缩回传感器无法在转印
带离合器开启后的预定时间间隔内检测到转印带是否
位于其加压位置。
Description
Transfer belt pressure welding alienation
The transfer belt retraction sensor does not detect “switch from retraction to pressure” within a given period time after transfer belt retraction clutch has stared engagement. The transfer belt retraction sensor does not detect “switch from pressure to retraction” within a given period time after transfer belt retraction clutch has stared engagement.
Remedy
1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary.
2 Check the connector of M1 for proper drive coupling and correct as necessary.
3 Check the connector between PS39-relay CN124-PRCB CN3 for proper connection and correct as necessary.
4 Check the connector between CL5-relay CN103-PRCB CN24 for proper connection and correct as necessary.
5 PS39 I/O check, sensor check PRCB CN3-15 (ON)
6 CL5 operation check PRCB CN24-4 (ON)
7 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5
8 Change M1.
9 PRCB ICP5 conduction check.
10 Change PRCB.