三星2071错误#S7-2110
更新时间:2026/11/12 20:10:35,view:357苏州三星2071打印机售后服务中心客服热线69616769,苏州三星打印机售后维修电话,三星打印机售后网点,三星20712071维修视频2026/9/7
三星2071错误#S7-2110
三星2071售后技术论坛 小马 2018/7/21 20:58:54 苏州维修电话696l6769 S7-2110
Display
Fuser Failure: #S7-2110. Turn off then on
Description
The fuser unit is overheated.
Remedy
1) Turn the machine off. Re-install the fuser unit. Then turn the machine on.
2) Remove the fuser unit. After open the jam cover, check jammed or wrapped paper is in the fuser unit.
3) Check if the contact type thermistor(1404-001567) or Non-contact type thermistor(1404-001453)is broken.
4) If the problem persists, replace the Fuser unit(110V : JC91-01049A / 220V : JC91-01050A).
5) If the problem persists, replace the Main board(JC92-02452A) or FDB board(110V : JC44-00210A, 220V : JC44-00211A), SMPS(110V : JC44-00093A, 220V : JC44-00100A)
三星2071售后技术论坛 小马 2018/7/21 20:58:54 苏州维修电话696l6769 S7-2110Display
Fuser Failure: #S7-2110. Turn off then on
Description
The fuser unit is overheated.
Remedy
1) Turn the machine off. Re-install the fuser unit. Then turn the machine on.
2) Remove the fuser unit. After open the jam cover, check jammed or wrapped paper is in the fuser unit.
3) Check if the contact type thermistor(1404-001567) or Non-contact type thermistor(1404-001453)is broken.
4) If the problem persists, replace the Fuser unit(110V : JC91-01049A / 220V : JC91-01050A).
5) If the problem persists, replace the Main board(JC92-02452A) or FDB board(110V : JC44-00210A, 220V : JC44-00211A), SMPS(110V : JC44-00093A, 220V : JC44-00100A)
热门图文