惠普4025报错59.c0
更新时间:2026/11/13 21:40:18,view:288苏州惠普4025打印机售后服务中心客服热线69616769,苏州惠普打印机售后维修电话,惠普打印机售后网点,惠普4025HPcp提示59.F0,热凝器套件严重不足,转印套件严重不足,怎么清零,HPCP彩色打印不正常,HP出现热凝器不足,报59.FO错误,59.f0错误,HPCP提示59.fo,废粉仓报错清除,提示59:fo,打印机提示转印,错误代码59,F0, cp 报错41.7,CP定影温度调整,4025维修视频2026/11/13
Code 59.xx
Display 59.xx Error
Description Developer motor rotation error. (显影仓马达旋转错误)
Remedy
1. Reconnect the connector (J518) on the developing disengagement motor, the connector (J1005) on the driver PCA and the connector (J91) on the DC controller PCA.
2. Run the sensor test in the sensor monitor mode to verify that the developing disengagement sensor is functioning correctly. If it is not, replace the developing disengagement sensor unit.
3. Run the developing unit engagement and disengagement drive test in the actuator drive mode to verify that the disengagement mechanism is functioning correctly. If it is not functioning correctly, replace the developing disengagement motor.惠普4025报错59.c0
Display 59.xx Error
Description Developer motor rotation error. (显影仓马达旋转错误)
Remedy
1. Reconnect the connector (J518) on the developing disengagement motor, the connector (J1005) on the driver PCA and the connector (J91) on the DC controller PCA.
2. Run the sensor test in the sensor monitor mode to verify that the developing disengagement sensor is functioning correctly. If it is not, replace the developing disengagement sensor unit.
3. Run the developing unit engagement and disengagement drive test in the actuator drive mode to verify that the disengagement mechanism is functioning correctly. If it is not functioning correctly, replace the developing disengagement motor.惠普4025报错59.c0
网友相关回复如下:(以下网友回复只代表网友个人观点,不代表苏州办公耗材网观点)
热门图文