理光5000打印机功能性故障SC360
理光5000打印机功能性故障SC360SC360 the code could be a problem with the:
TD sensor (Vt high) The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
SC360 is the Black TD Sensor so check the black pcu especially the connector connecting it with the black dev unit.
苏州理光打印机维修电话696l6769,维修,售后服务
TD sensor (Vt high) The Vt value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 4.7V) with SP3020-002 for twenty counts. The [Vt - Vtref] value of the black, magenta, cyan, or yellow TD sensor exceeds the specified value (default: 5.0V) with SP3020-001.
SC360 is the Black TD Sensor so check the black pcu especially the connector connecting it with the black dev unit.
苏州理光打印机维修电话696l6769,维修,售后服务
网友相关回复如下:(以下网友回复只代表网友个人观点,不代表苏州打印机维修服务网观点)