Epson7600/9600液晶屏报错SERVICEREQ 00010000的解决方法
更新时间:2024/4/19 1:05:53,view:177epson打印机Epson7600/9600苏州epson打印机售后维修服务中心电话0512-696l6769,苏州epson维修点电话, epsonlq690k暂停灯亮, EPSONLQ80机器故障, epson3119开关灯 纸灯墨灯, epson 690K 更换针头, EPSON L455红色一个圆形按钮里面有一个三角形,
00010000 走纸马达读取错误
1.连接PF 传感器线有问题,或者是线插反了检查下图所示PF传感器
2。马达或传感器的连接短路
3,光栅盘 污损 传感器位置偏差 不读码盘
请参考下代码解释,实际情况实际对待
ErrorCode; 00010000 Description; PF Motor Encoder check error
Explanation During initial operation at power on or during PF Motor operation, there may be a case where the encoder pulse signal can not be recognized at specified intervals. In such a case, this message is displayed and the printer stops operating.
Cause of trouble Disconnected connector for the PF Encoder Sensor.
Disconnected connector for the PF Motor.
Broken wire for the PF Motor Encoder.
Inverted wiring for A and B pulses.
Inverted wiring for the PF Motor.
PF Motor short
PF Motor continuous excitation (voltage applied continuously, motor revolutions unusual)
Broken power supply fuse for the PF motor driver (on the Main Board )
Points to be checked 1. The PF Encoder Sensor and the PF Loop Scale must be free from dust and dirt or any other foreign matters.
2. Execute encoder checking by the Service Manual "1.4.6.1 Self Testing Menu (SELF TESTING)" (p.91) in "Maintenance Mode 2".
3. The PF Timing Belt must be free from any defects and the belt must be in proper tension.
4. The PF Roller must rotate smoothly, free from undue load.
5. Measure the resistance value of the PF Motor (17.9 ± 15% [Ω]). If the PF Motor is found in short mode, replace the BOARD ASSY.,MAIN at the same time.
6. All the harness must be connected properly and free from short circuit or broken wire.
Remedy 1. Check for dirt, paper dust or damage to the Loop Scale
2. Connect the PF Encoder Sensor connector or PF Motor connector.
3. PF Timing Belt Tension Adjustment (Service Manual p.378)
4. Replace the PF Encoder Sensor (p.357)
5. Replace the Motor Assy., PF (p.349)
6. Replace the C593 MAIN Board (p.226)