EPSON 7600 液晶屏出现 SERVICE REQ 00010005解决方案
更新时间:2024/3/25 13:28:49,view:156EPSON 7600 打印机苏州北桥复印机维修服务中心电话0512-696l6769,苏州EPSON 7600 北桥维修站,EPSON 7600 北桥维修站, epson lq-680k pro 通讯错误, epson lq 690k 暂停灯亮, epson 2680打印跳行, EPSON1390电源板输出cn2 1-9针脚, EPSON1390电源板cn21-9针脚,
将正常关机时固定打印头的哪个件---字车锁(见下图)用橡皮筋绑下去即可.
最好拆除字车锁
其他,
如下代码表解释的,这也有可能是字车轮 皮带轮 CR光栅 传感器 主板 电机 等部件问题 请实际情况实际 对待
ErrorCode; 00010005 Description; CR Motor out of step
Explanation During CR Motor operation, there may be a case where the encoder pulse signal within the specified range is not input within a specified period of time or the pulse width is extremely long or short. In such a case, the CR Motor is judged to be out-of-step, so that this message is displayed and the printer stops operating.
Cause of trouble Defective CR Motor.
CR Motor driver damage (42V system short)
Broken temperature fuse for Cutter Solenoid.
Points to be checked 1. CR Scale is disconnected from CR Encoder Sensor.
2. The CR Encoder and the CR scale must be free from dust and dirt or any other foreign matters.
3. Execute encoder checking by the Service Manual "1.4.6.1 Self Testing Menu (SELF TESTING)" (p.91) in "Maintenance Mode 2".
4. The CR Timing Belt must be free from any defects and the belt must be in proper tension.
5. Execute the CR_hp Sensor checking by the "1.4.6.1 Self TestingMenu (SELF TESTING)" (p.91) in "Maintenance Mode 2".
6. The Carriage Unit must slide smoothly, free from undue load.
7. Measure the resistance value of the CR Motor. (17.9 ± 10% [Ω])
8. All the harness must be connected properly and free from short circuit or broken wire.
Remedy 1. Check to see if the CR Scale for detection of the encoder pulse is removed
2. Check for dirt, paper dust or damage to the CR Scale.
3. Perform the CR Timing Belt Tension Adjustment (Service Manual p.376)
4. Replace the CR Encoder Sensor (p.280)
5. Replace the CR_hp Sensor (p.276)
6. Replace the Motor Assy., CR (p.270)
7. Replace the C593 MAIN Board (p.226)
8. Replace the Cutter Solenoid
热门图文