震旦adc218出现c2152要怎么解决
更新时间:2024/3/23 5:41:27,view:145震旦打印机adc218苏州震旦常熟一体机维修点电话0512-696l6769,苏州震旦adc218常熟维修站,震旦adc218常熟维修站, 震旦adc225打印机故障代码c6901, 震旦289维修密码, 震旦记忆不足作业被删除, 震旦188出代码5102, 震旦ad228e载体初始化,
震旦adc218 金戟永 2018/11/18 11:03:49 Code C2152
Description Transfer belt pressure welding alienation
• The transfer belt retraction sensor does not detect “switch from retraction to pressure” within a given period time after transfer belt retraction clutch has stared engagement. • The transfer belt retraction sensor does not detect “switch from pressure to retraction” within a given period time after transfer belt retraction clutch has stared engagement.
Remedy
1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary.
2 Check the connector of M1 for proper drive coupling and correct as necessary.
3 Check the connector between PS39-relay CN124-PRCB CN3 for proper connection and correct as necessary.
4 Check the connector between CL5-relay CN103-PRCB CN24 for proper connection and correct as necessary.
5 PS39 I/O check, sensor check PRCB CN3-15 (ON)
6 CL5 operation check PRCB CN24-4 (ON)
7 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5
8 Change M1.
9 PRCB ICP5 conduction check.
10 Change PRCB.
震旦158b 蒋弄妮 2018/12/28 20:56:34 开机的时候出现异响,并且跳错误代码C2152,特别是打印彩色图片的时候更容易出现这个代码,把转印带拉出来整一整,侧盖的转印座也清洁一下就可以,用一段时间又出同样故障,到底是哪里出问题需换什么配件,C2152是转印带释放压力系统的问题! 转印带压合分离器故障。 转印带缩回操作期间,转印带缩回传感器无法在转印 带缩回离合器开启后的预定时间间隔内检测到转印带 是否位于其缩回位置。