震旦复印机adc218出现c-2152
更新时间:2024/4/14 18:02:03,view:88震旦打印机adc218苏州震旦打印机售后维修服务中心电话0512-696l6769,苏州震旦维修点电话, 震旦3425故障, 震旦ad199c0211, 震旦ad207载体初始化步骤, 震旦188打印机管理员密码, 震旦AD199维修召唤C3451视频,
Code C2152
转印带缩回操作期间,转印带缩回传感器无法在转印
带缩回离合器开启后的预定时间间隔内检测到转印带
是否位于其缩回位置。
转印带加压操作期间,转印带缩回传感器无法在转印
带离合器开启后的预定时间间隔内检测到转印带是否
位于其加压位置。
Description
Transfer belt pressure welding alienation
The transfer belt retraction sensor does not detect “switch from retraction to pressure” within a given period time after transfer belt retraction clutch has stared engagement. The transfer belt retraction sensor does not detect “switch from pressure to retraction” within a given period time after transfer belt retraction clutch has stared engagement.
Remedy
1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary.
2 Check the connector of M1 for proper drive coupling and correct as necessary.
3 Check the connector between PS39-relay CN124-PRCB CN3 for proper connection and correct as necessary.
4 Check the connector between CL5-relay CN103-PRCB CN24 for proper connection and correct as necessary.
5 PS39 I/O check, sensor check PRCB CN3-15 (ON)
6 CL5 operation check PRCB CN24-4 (ON)
7 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5
8 Change M1.
9 PRCB ICP5 conduction check.
10 Change PRCB.