震旦218提示错误代码c-2152
更新时间:2026/11/19 3:20:21,view:151苏州震旦218打印机售后服务中心客服热线69616769,苏州震旦打印机售后维修电话,震旦打印机售后网点,震旦218ADC错误代码P21,为什么打印出来的字上面有一行不清楚,DCP-5P-28,ad错误代码c-2557,adc请正确安装显影组件,并产上所有门,adc一直显示手动纸盒无匹配纸张怎么回事,ACD最厚能打多厚的纸,ADCP-21,出现C-2A01,机代码p5.p21,adc出现c-2654错误代码,错误代码c-2152,c彩色复印机出现p6,p7,p8,p9,p21代码是什么原因,ADC故障代码C-2654,218维修视频2026/11/19
苏州震旦维修电话696l6769,维修现场维修
Code C2152
转印带缩回操作期间,转印带缩回传感器无法在转印
带缩回离合器开启后的预定时间间隔内检测到转印带
是否位于其缩回位置。
转印带加压操作期间,转印带缩回传感器无法在转印
带离合器开启后的预定时间间隔内检测到转印带是否
位于其加压位置。
Description
Transfer belt pressure welding alienation
The transfer belt retraction sensor does not detect “switch from retraction to pressure” within a given period time after transfer belt retraction clutch has stared engagement. The transfer belt retraction sensor does not detect “switch from pressure to retraction” within a given period time after transfer belt retraction clutch has stared engagement.
Remedy
1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary.
2 Check the connector of M1 for proper drive coupling and correct as necessary.
3 Check the connector between PS39-relay CN124-PRCB CN3 for proper connection and correct as necessary.
4 Check the connector between CL5-relay CN103-PRCB CN24 for proper connection and correct as necessary.
5 PS39 I/O check, sensor check PRCB CN3-15 (ON)
6 CL5 operation check PRCB CN24-4 (ON)
7 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5
8 Change M1.
9 PRCB ICP5 conduction check.
10 Change PRCB.
震旦218提示错误代码c-2152
Code C2152
转印带缩回操作期间,转印带缩回传感器无法在转印
带缩回离合器开启后的预定时间间隔内检测到转印带
是否位于其缩回位置。
转印带加压操作期间,转印带缩回传感器无法在转印
带离合器开启后的预定时间间隔内检测到转印带是否
位于其加压位置。
Description
Transfer belt pressure welding alienation
The transfer belt retraction sensor does not detect “switch from retraction to pressure” within a given period time after transfer belt retraction clutch has stared engagement. The transfer belt retraction sensor does not detect “switch from pressure to retraction” within a given period time after transfer belt retraction clutch has stared engagement.
Remedy
1 Check the connector between M1-PRCB CN14 for proper connection and correct as necessary.
2 Check the connector of M1 for proper drive coupling and correct as necessary.
3 Check the connector between PS39-relay CN124-PRCB CN3 for proper connection and correct as necessary.
4 Check the connector between CL5-relay CN103-PRCB CN24 for proper connection and correct as necessary.
5 PS39 I/O check, sensor check PRCB CN3-15 (ON)
6 CL5 operation check PRCB CN24-4 (ON)
7 M1 operation check PRCB CN14-2 (REM) PRCB CN14-5 (LOCK) C-2 to 5
8 Change M1.
9 PRCB ICP5 conduction check.
10 Change PRCB.