苏州维修电话696l6769,> 维修资料 > hp > 苏州HP Color LaserJet CP1525售后维修电话696l6769> 苏州hp打印机维修服务网

hp Color LaserJet CP1525常见故障代码描述,英文手册

更新时间:2026/11/21 23:19:33,view:214

苏州hp1525打印机售后服务中心客服热线69616769,苏州hp打印机售后维修电话,hp打印机售后网点,hp1525提示卡纸,CPN的打印机,每打印两到三页.,n连接电脑打印有时候两侧会出现l蓝色的条,cpcn恢复出厂,CPN打印机打印有宽道道,打出来脏脏的,打印机怎么换搓纸轮,N打印重影,打印单张正常,打印两张就提示卡纸,n打印重影,打印机怎么只能打一张,打印机提示removeshippinglockfrommagem,n黄灯闪,[打印重影,1525维修视频2026/11/16

Code: 10.XXXX
Display:
10.XXXX Supply error
Description:
The e-label for one of the print cartridges cannot be read or is missing.
• 10.0000 = black e-label error • 10.0001 = cyan e-label error • 10.0002 = magenta e-label error • 10.0003 = yellow e-label error • 10.1000 = black e-label is missing • 10.1001 = cyan e-label is missing • 10.1002 = magenta e-label is missing • 10.1003 = yellow e-label is missing
Remedy:
Reinstall the print cartridge. Turn the product off and then on. If the problem is not solved, replace the print cartridge.
Code: 49
Display:
49 Error
Description:
The product experienced an internal error.
Remedy:
Turn the product off, wait at least 30 seconds, and then turn the product on and wait for it to initialize. If you are using a surge protector, remove it. Plug the product directly into the wall socket. Turn the product power on.
Code: 50.10
Display:
50.10 Fuser error
Description:
Fuser is defective (abnormal high temperature of the thermistor)
Remedy:
1. Reconnect the connectors of the fuser unit (J802) and DC controller PCA (J104). 2. Measure the resistance between the connector J802-1 and J802-3 on the fuser. If the resistance is not within the range from approximately 220 kOhm to 660 k (at ambient temperatures), replace the fuser. 3. Replace the fuser power supply unit.
Code: 50.12
Display:
50.12 Fuser error
Description:
Fuser is defective (Fuser 1 pressure release mechanism failure)
Remedy:
1. Reconnect the connectors of the DC controller PCA (J110, J115). 2. Check the sensor flag of the fuser pressure release sensor. If the sensor flag is damaged, replace it. 3. Replace the fuser motor. 4. Replace the high-voltage power supply unit. 5. Replace the fuser unit.
Code: 50.2
Display:
50.2 Fuser error
Description:
Fuser is defective (warm-up failure)
Remedy:
1. Reconnect the connectors of the fuser unit (J802) and DC controller PCA (J104). 2. Measure the resistance between the connector J801-1 and J801-3 on the fusier. If the resistance is not within the range from approximately 220 kOm to 660 kOm (at ambient temperatures), replace the fuser. 3. Reconnect the connectors of the fuser power supply unit (J201, J202, J203). 4. Measure the resistance between the connector J801-1 and J801-2 on the fuser. If the resistance is not within the range from approximately 21 0hm to 25 Ohm (at ambient temperatures), replace the fuser. 5. If the message persists, replace the fuser power supply unit.
Code: 50.3
Display:
50.3 Fuser error
Description:
Fuser is defective (abnormally low temperature of the thermistor)
Remedy:
1. Reconnect the connectors of the fuser (J802) and DC controller PCA (J104). 2. Measure the resistance between the connector J802-1 and J802-3 on the fuser. If the resistance is not within the range from approximately 220 kO to 660 kO (at ambient temperatures), replace the fuser. 3. Reconnect the connectors of the fuser power supply unit (J201, J202, J203). 4. Measure the resistance between the connector J801-1 and J801-2 on the fuser. If the resistance is not within the range from approximately 21 O to 25 O (at ambient temperatures), replace the fuser. 5. Replace the fuser. 6. Replace the fuser power supply unit.
Code: 50.6
Display:
50.6 Fuser error
Description:
Fuser is defective (drive circuit failure)
Remedy:
1. Reconnect the connectors of the fuser power supply unit (J201, J202, J203) and DC controller PCA (J105). 2. Check the power source. If the power generator is used, improve the situation. NOTE: If the product does not meet the power requirement of 40 to 70Hz frequency, the fuser temperature control does not work properly and this causes malfunction. 3. Replace the fuser power supply unit.
Code: 51.XX
Display:
51.XX Error
Description:
Optical unit is defective.
Remedy:
Reconnect the connectors of the laser driver PCA (J501) and the DC controller PCA (J108, J109). If the problem is not solved, replace the product.
Code: 54.XX
Display:
54.XX Error
Description:
The product has experienced a density sensor error.
Remedy:
at least 30 seconds, and then turn the product power on and wait for it to initialize. If you are using a surge protector, remove it. Plug the product directly into the wall socket. Turn the product power on.
Code: 55.X
Display:
55.X Error
Description:
The product has experienced a DC controller memory error.
Remedy:
Turn the product power off, wait at least 30 seconds, and then turn the product power on and wait for it to initialize. If you are using a surge protector, remove it. Plug the product directly into the wall socket. Turn the product power on.
Code: 57
Display:
57 Fan error
Description:
The product has experienced a problem with its internal fan.
Remedy:
Turn the product power off, wait at least 30 seconds, and then turn the product power on and wait for it to initialize. If you are using a surge protector, remove it. Plug the product directly into the wall socket. Turn the product power on.
Code: 59.20
Display:
59.X Error
Description:
The product has experienced a problem with one of the motors.
Main motor is defective (start-up failure)
Remedy:
Turn the product power off, wait at least 30 seconds, and then turn the product power on and wait for it to initialize. If you are using a surge protector, remove it. Plug the product directly into the wall socket. Turn the product power on. If the problem is not solved, follow these steps. 1. Reconnect the connectors of the main motor (J701) and DC controller PCA (J121). 2. If the problem persists, replace the main motor.
Code: 59.30
Display:
59.X Error
Description:
The product has experienced a problem with one of the motors.
Main motor is defective (rotational failure)
Remedy:
Turn the product power off, wait at least 30 seconds, and then turn the product power on and wait for it to initialize. If you are using a surge protector, remove it. Plug the product directly into the wall socket. Turn the product power on. If the problem is not solved, follow these steps. 1. Reconnect the connectors of the main motor (J701) and DC controller PCA (J121). 2. If the problem persists, replace the main motor.
Code: 79
Display:
79 Error
Description:
The product has experienced an internal firmware error.
Remedy:
Turn the product power off, wait at least 30 seconds, and then turn the product power on and wait for it to initialize. If you are using a surge protector, remove it. Plug the product directly into the wall socket. Turn the product power on.
Code: 79
Display:
79 Service error
Description:
An incompatible DIMM is installed.
Remedy:
1. Turn the product power off. 2. Install a DIMM that the product supports. 3. Turn the product on.

热门图文

相关资料补充_苏州hp维修点售后电话_HPColorLaserJetCP1525维修手册_错误代码0512-69616769 更新日期2026/11/16 11:11:19,hp,,,1525

»hpcp1525打印两张后出现cleqningmisprintpress(ok) 380

»惠普CP1525N打印不出来黑色 172

»惠普CP1525自动打印白纸 145

»惠普1525打印机怎样恢复出厂设置 136

»HP1525N,打印前面几张,就一切正常,当选择打印超过10左右(有时或是6、7)张过后。就模糊了。最后就空白纸出来。取消后,重新打印,又清楚。 447

»HP1525N打印时提示jamintray2,是什么问题 768

»HPcp1525n打印红色重影校准也不好使 866

»HP1525我换完齿轮组后提示59.c0 383

»HPCP1525打印黑色不出原因 170

»惠普1525报代码59.c0,请教下是什么问题 131

»hpcp1525提示59.a0 640

»hp1525N彩色打印机怎么打印出来无彩色 725

»惠普cp1525ncolor无法打印黑色 125

»hp1525打印机连续打印第一张正常,第二张显示2纸盒卡纸,请问是什么原因?按OK键后, 255

»hpcp1525彩色激光机打不出黑色 144


hp打印机HPColorLaserJetCP1525苏州唯亭hp售后服务电话0512-696l6769,苏州hpHPColorLaserJetCP1525售后电话,hpHPColorLaserJetCP1525唯亭售后网点,hpHPColorLaserJetCP1525维修手册,hpHPColorLaserJetCP1525驱动程序下载,hpHPColorLaserJetCP1525打印机售后维修点,hpHPColorLaserJetCP1525厂家电话,故障代码在线技术交流,有问必答,hpHPColorLaserJetCP1525卡纸,打印浅,亮红灯,不通电,无法使用等故障自己查询维修资料即可解决问题