Code: 12.8:10
Description:
Printmech: Hannibal2 24V failure. Check Spit-on roller motor and Primer motor
Causes:
The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Check the Spit-on roller motor and Primer motor. 2. Check the Printmech PCA.
Code: 12.9:10
Description:
Printmech: Hannibal3 24V failure. Check Inner lights array 1
Causes:
The 24V cable from Printmech to Inner lights array 1 has a problem Printmech PCA is damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Check the Inner lights array 1. 2. Check the Printmech PCA.
Code: 13.3:10
Description:
Printmech 12V_BULLI_2 to Vapor Removal PCA out of range
Causes:
The Printmech 12V_BULLI_2 to Vapor Removal PCA is out of range.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Check the Printmech cable to Vapor Removal PCA. 2. Check the Printmech PCA.
Code: 14.73:01
Description:
Curing power regulator V lower than 60: V lower than 60
Causes:
Heater Control AC Input (RCCB, AC Voltage Outlet, AC Power Cord) Heater Control.
Remedy:
Call agent: 1. Check that both Residual Circuit Breakers (RCCBs) are Powered and ON. 2. Check/Reseat both Power Cords. Service engineer: 1. Check AC Voltage at customer's site (180-264Vac). 2. Reseat/Replace cables to Heater Control's AC input. 3. Replace the Heater Control.
Code: 14.74:01
Description:
Curing power regulator V lower than 140
Causes:
V lower than 140
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Check the input voltage.
Code: 14.75:01
Description:
Curing power regulator V bigger than Vmax
Causes:
V bigger than Vmax
Remedy:
1. Check the input voltage. 2. Run Service "Curing system monitor".
Code: 14.76:11
Description:
Curing power regulator V could not be read
Causes:
Curing Control PCA Cable to Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Reseat/Replace Curing Control PCA Cable to Heater Control.
Code: 14.77:10
Description:
Curing power regulator control signal failure
Causes:
Control signal failure
Remedy:
Service engineer: • Replace the Control PCA to Heater Control and Control PCA cables.
Code: 14.80:10
Description:
Curing power regulator current not null
Causes:
Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Replace the Heater Control.

Code: 14.81:10
Description:
Curing power regulator current too high
Causes:
Heaters, Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Check heaters with a tester and replace heaters if necessary (shortcut). 3. Replace the Heater Control.
Code: 14.82:10
Description:
Curing power regulator shortcut
Causes:
Heaters, Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Check heaters with a tester and replace heaters if necessary (shortcut). 3. Replace the Heater Control.
Code: 14.83:11
Description:
Curing power regulator open circuit
Causes:
Heater Control to Curing Power Interconnect PCA Cable. Curing Power Interconnect PCA Curing Cable. Curing Resistor.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Reseat/Replace the Heater Control to Curing Power Interconnect PCA Cables. 3. Reseat/Replace Curing Power Interconnect PCA Curing Cable. 4. Reseat/Replace all Curing Resistors connectors.
Code: 14.87:10
Description:
Curing power regulator OverTemp
Causes:
Power regulator OverTemp.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. If the SE appears frequently, replace the Heater Control.
Code: 14.88:10
Description:
Curing power regulator overvoltage or shortcut
Causes:
Regulator overvoltage or shortcut.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Check resistor module values, If they are ok, check installation.
Code: 14.89:10
Description:
Curing power regulator relay damaged
Causes:
Heater Control.
Remedy:
Service engineer: 1. Run Service "Curing system monitor". 2. Replace de Heater Control.
Code: 15.20:10
Description:
Cable or Resistor shortcircuit from any PZ or vapor resistor
Causes:
Shortcircuit from Any PZ or vapor resistor.
Remedy:
Service engineer: • Check the PZ resistors, the Vapor resistors, or cable shortcircuits. Replace the affected part.
Code: 15.31:10
Description:
PZ resistor 1: Cable or resistor shortcircuit
Causes:
Cable or resistor shortcircuit.
Remedy:
Service engineer: • Check the PZ resistor 1 or cable shortcircuit.
Code: 15.32:10
Description:
PZ resistor 2: Cable or resistor shortcircuit
Causes:
Cable or resistor shortcircuit.
Remedy:
Service engineer: • Check the PZ resistor 2 or cable shortcircuit.
Code: 15.33:10
Description:
PZ resistor 3: Cable or resistor shortcircuit
Causes:
Cable or resistor shortcircuit.
Remedy:
Service engineer: • Check the PZ resistor 3 or cable shortcircuit.
Code: 15.41:11
Description:
PZ resistor 1: Not connected
Causes:
PZ Heaters Cable PZ Resistor 1 Air Curtain and Printzone Heaters Control PCA.
Remedy:
• Restart the printer. Service engineer: 1. Reseat/Replace Air Curtain and Printzone Heaters Control PCA to PZ Heaters cable. 2. Reseat/Replace PZ Resistor 1.
Code: 15.42:11
Description:
PZ resistor 2: Not connected
Causes:
PZ resistor 2 disconnected or damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: • Check that PZ 2 resistor is properly connected. If it is, then replace PZ 2 resistor.
Code: 15.43:11
Description:
PZ resistor 3: Not connected
Causes:
PZ resistor 3 disconnected or damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: • Check that PZ 3 resistor is properly connected. If it is, then replace PZ 3 resistor.
Code: 15.51:03
Description:
PZ resistor 1: Out of range
Causes:
Resistor out of range.
Remedy:
Service engineer: • Measure the PZ 1 resistance. Replace in case of resistance out of range.
Code: 15.52:03
Description:
PZ resistor 2: Out of range
Causes:
Resistor out of range.
Remedy:
Service engineer: • Measure the PZ 2 resistance. Replace in case of resistance out of range.
Code: 15.53:03
Description:
PZ resistor 3: Out of range
Causes:
Resistor out of range.
Remedy:
Service engineer: • Measure the PZ 3 resistance. Replace in case of resistance out of range.

Code: 15.60:10
Description:
PZ fan fault or not connected
Causes:
Fan fault or not connected
Remedy:
Service engineer: • Check that the PZ fans are properly connected. If they are, then replace them.
Code: 15.61:10
Description:
PZ fan 1 fault or not connected
Causes:
PZ fan 1 disconnected or damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: • Check that PZ 1 fan is properly connected. If it is, then replace PZ 1 fan.
Code: 15.62:10
Description:
PZ fan 2 fault or not connected
Causes:
PZ fan 2 disconnected or damaged.
Remedy:
Call agent: • Restart the printer. Service engineer: • Check that PZ 2 fan is properly connected. If it is, then replace PZ 2 fan.
Code: 15.63:10
Description:
PZ fan 3 fault or not connected
Causes:
PZ fan 3 disconnected or damaged.
Remedy:
Service engineer: • Check that PZ 3 fan is properly connected. If it is, then replace PZ 3 fan.
Code: 15.69:10
Description:
More than 1 PZ fan fault or not connected
Causes:
PZ Heaters Fan Cable PZ Resistor Fan 1 Air Curtain and Printzone Heaters Control PCA.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Reseat/Replace Air Curtain and Printzone Heaters Control PCA to PZ Heaters Fan cable. 2. Reseat/Replace PZ Resistor Fan 1.
Code: 15.71:10
Description:
PZ fan 1: fan or cable damaged
Causes:
Fan or cable damaged.
Remedy:
Service engineer: • Replace the PZ fan 1.
Code: 15.72:10
Description:
PZ fan 2: fan or cable damaged
Causes:
Fan or cable damaged.
Remedy:
Service engineer: • Replace the PZ fan 2.
Code: 15.73:10
Description:
PZ fan 3: fan or cable damaged
Causes:
Fan or cable damaged.
Remedy:
Service engineer: • Replace the PZ fan 3.

Code: 15.79:10
Description:
More than 1 PZ fan or cable damaged
Causes:
More than 1 PZ fan or cable damaged.
Remedy:
Service engineer: • Replace the PZ fans.
Code: 16.01:00
Description:
Curing System unable to warm up in the pre-defined amount of time
Causes:
Ambient temperature below 15oC. Low AC Voltage. Fans (Curing, Air Curtain, PZ). Curing Resistors. Curing Temperature Sensor. Curing Pressure Sensor.
Remedy:
1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer's operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer's location. 2. Check if the input voltage is outside the range of specifications for printing, see the Site Preparation Guide. 3. Run Service "Curing system monitor". 4. Check all Fans (Curing, Air Curtain, PZ), all spinning and no obstruction. 5. Reseat/Replace Curing Resistors. 6. Reseat/Replace Curing Temperature Sensors. 7. Reseat/Replace Curing Pressure Sensor.
Code: 16.02:00
Description:
Curing system: cool down timeout
Causes:
Ambient temperature above 30C Fans (Curing, Air Curtain, PZ).
Remedy:
Service engineer: 1. The environmental ambient temperature is too hot or is outside the operational specification of the printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters etc. 2. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed.
Code: 16.03:00
Description:
Curing system: high temperature error
Causes:
Ambient temperature above 30oC, Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.
Remedy:
1. The environmental ambient temperature is too hot or is outside the operational specification of the printer. Make sure there are no external sources of heat, such as strong lights, direct sunlight, heaters etc. 2. Run Service "Curing system monitor”. 3. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed. 4. Reseat/Replace Curing Resistors. 5. Reseat/Replace Curing Temperature Sensors. 6. Reseat/Replace Curing Pressure Sensor.
Code: 16.04:00
Description:
Curing system: low temperature error
Causes:
Ambient temperature below 15oC, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.
Remedy:
1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer's operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer's location. 2. Check the input voltage is outside the range of specifications for printing, see the Site Preparation Guide. 3. Run Service "Curing system monitor. 4. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed. 5. Reseat/Replace Curing Resistors. 6. Reseat/Replace Curing Temperature Sensors. 7. Reseat/Replace Curing Pressure Sensor.
Code: 16.05:00
Description:
Curing system: temperature sensor error
Causes:
Curing Control PCA Temperature Sensors Cable Temp. Sensors.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Run Service "Curing system monitor". 2. Reseat/replace Curing Control PCA Temperature Sensors Cable. 3. Reseat/replace Temp. Sensors.
Code: 16.07:03
Description:
Curing system: warm up timeout (uniformity)
Causes:
Ambient temperature below 15oC, Low AC Voltage Fans (Curing, Air Curtain, PZ), Curing Resistors, Curing Temperature Sensor, Curing Pressure Sensor.
Remedy:
1. Check if the environmental ambient temperature is low. Check the surrounding temperature is within the printer's operating specifications; it should be higher than 15C for printer operation. If this is the case, increase the ambient temperature of the printer's location. 2. Check the input voltage is outside the range of specifications for printing, see the Site Preparation Guide. 3. Run Service "Curing system monitor. 4. Check all Fans (Curing, Air Curtain, PZ), are rotating, and unobstructed. 5. Reseat/Replace Curing Resistors. 6. Reseat/Replace Curing Temperature Sensors. 7. Reseat/Replace Curing Pressure Sensor.
Code: 16.11:10
Description:
Curing System: Temperature sensor 1 failure or not connected
Causes:
Curing Control PCA Sensors cable Temp. sensor 1.
Remedy:
Call agent: • Restart the printer. Service engineer: 1. Reseat/replace Curing Control Sensors cable. 2. Reseat/replace Temp. sensor 1.

Code: 16.12:10
Description:
Curing System: Temperature sensor 2 failure or not connected
Causes:
Temperature sensor 2.
Remedy:
Call agent: • Restart the printer. Service engineer: • Reseat/replace Temp. sensor 2.
Code: 16.13:10
Description:
Curing System: Temperature sensor 3 failure or not connected
Causes:
Temperature sensor 3.
Remedy:
Call agent: • Restart the printer. Service engineer: • Reseat/replace Temp. sensor 3.
Code: 16.14:10
Description:
Curing System: Temperature sensor 4 failure or not connected
Causes:
Temperature sensor 4.
Remedy:
Call agent: • Restart the printer. Service engineer: • Reseat/replace Temp. sensor 4.
Code: 16.31:10
Description:
Curing system: Fan 1 fault
Causes:
Curing system: Fan 1 fault.
Remedy:
Call agent: • Restart the printer. Service engineer: • Replace module 1.
Code: 16.32:10
Description:
Curing system: Fan 2 fault
Causes:
Curing system: Fan 2 fault.
Remedy:
Call agent: • Restart the printer. Service engineer: • Replace module 2.
Code: 16.33:10
Description:
Curing system: Fan 3 fault
Causes:
Curing system: Fan 3 fault.
Remedy:
Call agent: • Restart the printer. Service engineer: • Replace module 3.

热门图文

相关资料补充_苏州hp维修点售后电话_2维修手册_错误代码0512-69616769 更新日期2026/11/1 10:10:59,hp,,,300

»hp2300 硒鼓加粉后出现内存故障,问题原因? 392

»HP300彩机打印红色不对位置偏移 230

»HP lasejet P3005 is showing this message 49.FF07 Service error, what can i do to solve this problem 917

»HP M1005 一体机上的12A硒鼓,最近2次加粉总是印到1200-1300页的时候废粉就满了,导致废粉溢出,如何处理? 616

»hp3005硒鼓在客户出打印有问题,在公司的机器上试没问题,看看怎么解决? 460

»HP LaserJet Pro 300 M375 MFP常见故障代码描述,英文手册 118

»HP LaserJet P3005dn常见故障代码描述,英文手册1 131

»HP LaserJet P3005n常见故障代码描述,英文手册1 95

»hpf300打印机怎么校正打印头 124

»HP LaserJet P3005n常见故障代码描述,英文手册2 147

»hpp3005每次打印都没反应,必须按两次打印机上的对号按钮才能从纸盒2打印老是提示“在纸盒1中装入普通纸”,注意灯一直在闪烁,请问有哪位大侠知道怎么解决? 1105

»HP3300有时正常有时检测不到扫描头怎么处理? 165

»HP LaserJet P3005常见故障代码描述,英文手册1 117

»HP LaserJet P3005常见故障代码描述,英文手册2 212

»hp p3005n 开机后过一会就死机,显示屏没没应,有时会提示49.FF05 SERVICE ERROR,问题原因 1612


hp打印机HPLatex300苏州沧浪新城hp售后服务电话0512-696l6769,苏州hpHPLatex300售后电话,hpHPLatex300沧浪新城售后网点,hpHPLatex300维修手册,hpHPLatex300驱动程序下载,hpHPLatex300打印机售后维修点,hpHPLatex300厂家电话,故障代码在线技术交流,有问必答,hpHPLatex300卡纸,打印浅,亮红灯,不通电,无法使用等故障自己查询维修资料即可解决问题