苏州sharp打印机维修服务网 > 维修资料 > sharp > 苏州Sharp ARC330售后维修电话696l6769 > 正文

Sharp ARC330常见故障代码描述,英文手册2

Code: F2 45
Description:
Image density sensor trouble (COLOR)(Calibration plate reflection abnormality)
Causes:
"In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed."
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output)(SIM44-2) / Check the image density sensor calibration plate. / Check the operation of the image density sensor calibration plate switching." (Repair) Clean or replace the image density sensor. / Clean or replace the image density sensor calibration plate. / Replace the image density sensor calibration plate switch solenoid. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from the transfer belt, the OPC drum unit, and the developing unit" (Repair) Clean or replace the transfer belt. / Replace the transfer belt cleaner. / Clean the OPC drum and the developing unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUM PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
Code: F2 50
Description:
Drum marking detection trouble (BLACK)
Causes:
The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy:
Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Code: F2 51
Description:
Drum marking detection trouble (CYAN)
Causes:
The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy:
Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Code: F2 52
Description:
Drum marking detection trouble (MAGENTA)
Causes:
The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy:
Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Code: F2 53
Description:
Drum marking detection trouble (YELLOW)
Causes:
The drum marking is not recognized. / The size and the number of drum markings are not specified ones.
Remedy:
Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output)" Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. Remedy (Check) Check connection of the signal line of PCU MAIN PWB / process control PWB / drum marking sensor. (Repair) Repair or replace the cable and the connector between PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
.
Code: F2 54
Description:
Drum marking sensor gain adjustment error (BLACK)
Causes:
"In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed."
Remedy:
Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output) " Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor Remedy (Check) Check connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor. (Repair) Repair or replacement of the cable and the connector between the PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Code: F2 55
Description:
Drum marking sensor gain adjustment error (CYAN)
Causes:
"In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed."
Remedy:
Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output) " Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON Case 2 Trouble position/cause Bad connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor Remedy (Check) Check connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor. (Repair) Repair or replacement of the cable and the connector between the PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Code: F2 56
Description:
Drum marking sensor gain adjustment error (MAGENTA)
Causes:
"In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed."
Remedy:
Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output) " Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor Remedy (Check) Check connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor. (Repair) Repair or replacement of the cable and the connector between the PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Code: F2 57
Description:
Drum marking sensor gain adjustment error (YELLOW)
Causes:
"In the image density correction, the transfer belt surface is read by the image density sensor and the sensor gain is adjusted so that the output becomes a fixed value. However, the output of the specified range cannot be obtained even though the sensor gain is changed."
Remedy:
Case 1 Trouble position/cause "Drum marking sensor trouble (dirt, output) " Remedy (Check) Drum marking sensor output check (SIM44-2) (Repair) Clean or replace the drum marking sensor. / Power Source-ON (After-work) Note Case 2 Trouble position/cause Bad connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor Remedy (Check) Check connection of the signal line between PCU MAIN PWB / Process control PWB / Drum marking sensor. (Repair) Repair or replacement of the cable and the connector between the PCU MAIN PWB / Process control PWB / Drum marking sensor. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 4 Trouble position/cause "OPC drum surface dirt, scratch / A different type of OPC drum is installed." Remedy (Check) "Check dirt and scratches on the OPC drum surface, and the type of OPC drum." (Repair) Clean the OPC drum surface. / Replace the OPC drum. / Power Source-ON (After-work) Refer to the requirement item 2 of maintenance servicing and consumable parts replacement.
Code: F2 58
Description:
Process humidity sensor trouble
Causes:
Humidity concentration sensor output line open
Remedy:
Case 1 Trouble position/cause Bad connection between the image density sensor and the PCU SUB PWB. Remedy (Check) Check connection of the image density sensor and the PCU SUB PWB. (Repair) Replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON
Code: F2 63
Description:
Temperature sensor trouble (Image process)
Causes:
Temperature sensor (image process) output line open
Remedy:
Case 1 Trouble position/cause "Bad connection of the temperature sensor, the process control PWB, and the PCU MAIN PWB." Remedy (Check) "Check connection of the temperature sensor, the process control PWB, and the PCU MAIN PWB." (Repair) Replace the temperature sensor (process control PWB). / Power Source-ON (After-work) Note Case 2 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) Check the output level of the PCU MAIN PWB humidity sensor. (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
Code: F2 80
Description:
Half tone correction (1st patch) trouble (BLACK)
Causes:
"In half tone image density correction, the toner patch density is abnormally low or high."
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output).(SIM44-2)" (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit" (Repair) "Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning" / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)" / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
Code: F2 81
Description:
Half tone correction (1st patch) trouble (CYAN)
Causes:
"In half tone image density correction, the toner patch density is abnormally low or high."
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output).(SIM44-2)" (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit" (Repair) "Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning" / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)" / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10

Code: F2 82
Description:
Half tone correction (1st patch) trouble (MAGENTA)
Causes:
"In half tone image density correction, the toner patch density is abnormally low or high."
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output).(SIM44-2)" (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit" (Repair) "Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning" / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)" / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
Code: F2 83
Description:
Half tone correction (1st patch) trouble (YELLOW)
Causes:
"In half tone image density correction, the toner patch density is abnormally low or high."
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output).(SIM44-2)" (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit" (Repair) "Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning" / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Note Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)" / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
Code: F2 84
Description:
Half tone correction (2nd patch) trouble (BLACK)
Causes:
"In the half toner image density correction, the toner patch densities at the boundary sections of the low density area, the medium density area, and the high density area are abnormally different from each other."
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output).(SIM44-2)" (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit" (Repair) "Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning" / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)" / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
Code: F2 85
Description:
Half tone correction (2nd) patch trouble (CYAN)
Causes:
"In the half toner image density correction, the toner patch densities at the boundary sections of the low density area, the medium density area, and the high density area are abnormally different from each other."
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output).(SIM44-2)" (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit" (Repair) "Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning" / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)" / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
Code: F2 86
Description:
Half tone correction (2nd) patch trouble (MAGENTA)
Causes:
"In the half toner image density correction, the toner patch densities at the boundary sections of the low density area, the medium density area, and the high density area are abnormally different from each other."
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output).(SIM44-2)" (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit" (Repair) "Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning" / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
Code: F2 87
Description:
Half tone correction (2nd) patch trouble (YELLOW)
Causes:
"In the half toner image density correction, the toner patch densities at the boundary sections of the low density area, the medium density area, and the high density area are abnormally different from each other."
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output).(SIM44-2)" (Repair) Clean or replace the image density sensor. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from transfer belt cleaner, OPC drum unit, developing unit" (Repair) "Transfer belt cleaning, replacement / Transfer belt cleaner replacement / OPC drum unit, developing unit cleaning" / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB humidity sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)" / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
Code: F2 90
Description:
Half tone correction trouble
Causes:
The max. value of the difference (between colors) between the half tone correction value and the previous correction value exceeds the specified level.
Remedy:
Case 1 Trouble position/cause Image density sensor trouble Remedy (Check) "Check the image density sensor (dirt, output)(SIM44-2) / Check the image density sensor calibration plate. / Check the operation of the image density sensor calibration plate switching." (Repair) Clean or replace the image density sensor. / Clean or replace the image density sensor calibration plate. / Replace the image density sensor calibration plate switch solenoid. / Power Source-ON (After-work) Adjust ADJ M6 Note Case 2 Trouble position/cause "Transfer belt trouble (dirt, scratch)" Remedy (Check) "Toner dispersion from the transfer belt, the OPC drum unit, and the developing unit" (Repair) Clean or replace the transfer belt. / Replace the transfer belt cleaner. / Clean the OPC drum and the developing unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause PCU SUB PWB trouble Remedy (Check) Check the PCU SUB PWB image density sensor circuit. (Repair) PCU SUB PWB replacement / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.) Case 5 Trouble position/cause Main charger output trouble Remedy (Check) "Main charger contact check / Main charger unit check / High voltage power PWB, high voltage interface PWB check / Main charger output voltage check " (Repair) "Main charger unit replacement / High voltage power PWB, high voltage interface PWB replacement / Main charger output voltage adjustment (SIM 8-2)" / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 6 Trouble position/cause Developing bias output trouble Remedy (Check) Developing bias contact check / High voltage PWB check / Developing bias voltage check (Repair) High voltage power PWB replacement / Developing bias output voltage adjustment (SIM8-1) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 7 Trouble position/cause Transfer trouble Remedy (Check) Transfer roller check / High voltage power PWB check / Transfer voltage check (Repair) Transfer roller replacement / High voltage power PWB replacement / Transfer output voltage adjustment (SIM 8-6) / Power Source-ON (After-work) Execute the image density correction (SIM 44-6). / Execute the half tone density correction (SIM 44-26). Note Case 8 Trouble position/cause Scanner (writing) unit trouble (Scanner (writing) motor trouble / Laser beam sensor trouble / Internal optical system dirt) Remedy (Check) Check the operation of the scanner (writing) unit. (SIM 61-1) (Repair) Replace the scanner (writing) unit. / Power Source-ON (After-work) Adjust ADJM7/ADJM9/ADJM10
Code: F3 12
Description:
Lift up trouble (Paper 1)
Causes:
Lifting is not completed (LUD1) is not turned ON) within the specified time after turning ON the lift motor.
Remedy:
Case 1 Trouble position/cause LUD1 detector trouble Remedy (Check) Check operation of the LUD1 detector (SIM 30-2). (Repair) Replace the LUD1 detector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause "Lift mechanism (motor, etc.) trouble" Remedy (Check) "Check operations of the lift mechanism section (motor, etc.)." (Repair) replace the e lift unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Bad connection between the PCU MAIN PWB and the lift unit. Remedy (Check) Check connection between the PCU MAIN PWB and the lift unit. (Repair) Repair or replace the connector and cables of the PCU MAIN PWB and the lift unit. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)

Code: F3 22
Description:
Lift up trouble (Paper 2)
Causes:
Lifting is not completed (LUD2) is not turned ON) within the specified time after turning ON the lift motor.
Remedy:
Case 1 Trouble position/cause LUD2 detector trouble Remedy (Check) Check operation of the LUD2 detector (SIM 30-2). (Repair) Replace the LUD2 detector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause "Lift mechanism (motor, etc..) trouble" Remedy (Check) "Check operations of the lift mechanism section (motor, etc.)." (Repair) replace the e lift unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Bad connection between the PCU MAIN PWB and the lift unit. Remedy (Check) Check connection between the PCU MAIN PWB and the lift unit. (Repair) Repair or replace the connector and cables of the PCU MAIN PWB and the lift unit. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)
Code: F3 32
Description:
Lift up trouble (Paper 3)
Causes:
Lifting is not completed (LUD3) is not turned ON) within the specified time after turning ON the lift motor.
Remedy:
Case 1 Trouble position/cause LUD3 detector trouble Remedy (Check) Check operation of the LUD3 detector (SIM 30-2). (Repair) Replace the LUD3 detector. / Power Source-ON (After-work) Note Case 2 Trouble position/cause "Lift mechanism (motor, etc.) trouble" Remedy (Check) "Check operations of the lift mechanism section (motor, etc.)." (Repair) replace the e lift unit. / Power Source-ON (After-work) Note Case 3 Trouble position/cause Bad connection between the PCU MAIN PWB and the lift unit. Remedy (Check) Check connection between the PCU MAIN PWB and the lift unit. (Repair) Repair or replace the connector and cables of the PCU MAIN PWB and the lift unit. / Power Source-ON (After-work) Note Case 4 Trouble position/cause PCU MAIN PWB trouble Remedy (Check) (Repair) Replace the PCU MAIN PWB. / Power Source-ON (After-work) Re-enter setup values and adjustment values. (Install the EEPROM of the defective PCU MAIN PWB to a new PCU MAIN PWB.)

热门图文

相关资料补充


热门关注
· sharp arc330常见故障代码描述,英文手册1

· sharp arc360p常见故障代码描述,英文手册2

· sharp arc360p常见故障代码描述,英文手册1

· sharp arf151常见故障代码描述,英文手册

· sharp arf152常见故障代码描述,英文手册

· sharp arf160常见故障代码描述,英文手册

· sharp arf161常见故障代码描述,英文手册

· sharp arf200常见故障代码描述,英文手册

· sharp arf201常见故障代码描述,英文手册

· sharp arm150常见故障代码描述,英文手册

· sharp arm155常见故障代码描述,英文手册

· sharp arm160常见故障代码描述,英文手册

· sharp arm161常见故障代码描述,英文手册

· sharp arm162常见故障代码描述,英文手册

· sharp arm165常见故障代码描述,英文手册

· sharp arm200常见故障代码描述,英文手册

· sharp arm201常见故障代码描述,英文手册

· sharp arm205常见故障代码描述,英文手册

· sharp arm206常见故障代码描述,英文手册

· sharp arm207常见故障代码描述,英文手册

· sharp arm208常见故障代码描述,英文手册2

· sharp arm208常见故障代码描述,英文手册1

· sharp arm236常见故障代码描述,英文手册1

· sharp arm236常见故障代码描述,英文手册2

· sharp arm237常见故障代码描述,英文手册2

· sharp arm237常见故障代码描述,英文手册1

· sharp arm256常见故障代码描述,英文手册2

· sharp arm256常见故障代码描述,英文手册1

· sharp arm257常见故障代码描述,英文手册2

· sharp arm257常见故障代码描述,英文手册1

推荐文章
· sharpar2048打印机显示需要用户干预打印不成怎么办

· toshiba2303卡纸怎去除

· 东芝toshiba2303a打印机提示简易设置调整错误请按确定键重试

· sharp-mx2018uc 报l14-04代码,那位大师指点一下

· toshiba2303a复印机出现e140代码是什么意思

· sharp ar2008d打印清楚。复印很淡,手动清楚,调整方法

· sharp1808s扫描出现u-2

· toshibastudio2303a换碳粉

· sharp mxm700u常见故障代码描述,英文手册2

· sharp mxm654fn常见故障代码描述,英文手册1

· sharp mxm654fn常见故障代码描述,英文手册2

· sharp mxm654fn常见故障代码描述,英文手册3

· sharp mxm623u常见故障代码描述,英文手册1

· sharp mxm623u常见故障代码描述,英文手册2

· sharp mxm620u常见故障代码描述,英文手册01

· sharp mxm620u常见故障代码描述,英文手册02

· sharp mxm564n常见故障代码描述,英文手册01

· sharp mxm564n常见故障代码描述,英文手册02

· sharp mxm550u常见故障代码描述,英文手册01

· sharp mxm550u常见故障代码描述,英文手册02

· sharp mxm503n常见故障代码描述,英文手册1

· sharp mxm503n常见故障代码描述,英文手册2

· sharp mxm502n常见故障代码描述,英文手册2

· sharp mxm502n常见故障代码描述,英文手册1

· sharp mxm465n常见故障代码描述,英文手册2

· sharp mxm465n常见故障代码描述,英文手册1

· sharp mxm464n常见故障代码描述,英文手册1

· sharp mxm464n常见故障代码描述,英文手册2

· sharp mxm453n常见故障代码描述,英文手册1

· sharp mxm453n常见故障代码描述,英文手册2

· sharp mxm452n常见故障代码描述,英文手册2

· sharp mxm452n常见故障代码描述,英文手册1

· sharp mxm450n常见故障代码描述,英文手册1

· sharp mxm450n常见故障代码描述,英文手册2

· sharp mxm423f常见故障代码描述,英文手册1

· sharp mxm423f常见故障代码描述,英文手册2

· sharp mxm365n常见故障代码描述,英文手册2

· sharp mxm365n常见故障代码描述,英文手册1

· sharp mxm364n常见故障代码描述,英文手册1

· sharp mxm364n常见故障代码描述,英文手册2

· sharp mxm363n常见故障代码描述,英文手册2

· sharp mxm363n常见故障代码描述,英文手册1

· sharp mxm362n常见故障代码描述,英文手册1

· sharp mxm362n常见故障代码描述,英文手册2

· sharp mxm354n常见故障代码描述,英文手册1

· sharp mxm354n常见故障代码描述,英文手册2

· sharp mxm350n常见故障代码描述,英文手册1

· sharp mxm350n常见故障代码描述,英文手册2

· sharp mxm316n常见故障代码描述,英文手册2

· sharp mxm316n常见故障代码描述,英文手册1