konicaminolta维修召唤C3752
更新时间:2024/4/16 12:40:21,view:205minolta打印机konicaminolta苏州minolta打印机售后维修服务中心电话0512-696l6769,苏州维修点电话, konicaminolta 185双面打印, KONICA MINOLTA打印机错误代码, KONICA MINOLTA 错误代码C0211, konicaminolta185-8脱机如果解决?, minoltac2351维修召唤,
苏州minolta打印机售后维修服务中心电话0512-696l6769
苏州柯美打印机维修电话696l6769,现场解决,技术支持Code C3752
Description
Abnormally high fusing temperature (sub)
- The temperature detected by the thermistor/2 (TH2) is over the specified temperature for more than the specified period of time after power is turned ON.
Remedy
1 Check the fusing unit for correct installation.
2 Check the open/close operation of the right door.
3 Check the fusing unit, DCPU and MFPB for proper connection and correct or change as necessary.
4 Change fusing unit.
5 Change MFPB.
6 Change DCPU.