理光2014ad维修呼叫sc362-01
更新时间:2024/4/26 5:01:14,view:429理光打印机2014ad苏州理光打印机售后维修服务中心电话0512-696l6769,苏州理光维修点电话, 理光7001SC195, 理光1075启用打印组件代码, 理光MP6054 sc324-1故障, 理光7500代码672, 理光4454,版纸送版不畅故障?,
Code SC362-02
Description
TD sensor output error: Lower limit (C) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
Causes
TD sensor connector missing/dropout
Remedy
1. TD sensor connector missing check
2. Check whether there is any error in the TD sensor harness (disconnection, etc.)
3. If the sensor is defective, replace the development unit.