·C414定影器故障,跟换载体没关系
·Code C414
Description Fuser unit related service call. Thermistor abnormality during warming up or in ready status after abnormality judgment.
Causes MAIN board Thermistors Heater lamp
苏州东芝2303AM售后维修电话696l6769,企业一站式服务,上门维修,耗材配送
1. Turn ON the power while [0] , [8] are pressed simultaneously.
2. Key in "2002", then press [START].
3. Change the current status counter value "1" , "2" to "0", then press [OK] (to cancel [C413 / C414]).