理光2004Cdn打印两张之后直接报代码SC362-01,是啥问题
更新时间:2024/4/25 22:07:03,view:594理光打印机2004Cdn苏州理光打印机售后维修服务中心电话0512-696l6769,苏州理光维修点电话, 理光C3300 sc290, 理光打印机3504提示功能上问题, 理光c2800维修手册, 理光2012报错sc542清除方法, 理光5501显示sc364,
DescriptionTD sensor output error: Lower limit (C) TD sensor output: Vt (SP3-210-001 - 004) < output lower limit error threshold (SP3-211-004) is continuously below the lower limit occurrence threshold value (SP3-211-005)
CausesTD sensor connector missing/dropout
Remedy1. TD sensor connector missing check
2. Check whether there is any error in the TD sensor harness (disconnection, etc.)
3. If the sensor is defective, replace the development unit. 苏州理光2004Cdn售后维修电话696l6769,企业一站式服务,上门维修,耗材配送